Industrielles Netzteil

  • Industrielles Steuerungssystem
  • Fabrikautomatisierung
  • Elektromechanische Vorrichtung
View Less
View more

Spezifikation

  • OUTPUT
  • DC VOLTAGE48V
  • RATED CURRENT(forBETypeonly) 10A
  • RATED POWER480W
  • RIPPLE & NOISE (max.) Note.3150mVp-p
  • VOLTAGE ADJ. RANGE48 ~ 55V
  • VOLTAGE TOLERANCE Note.4 ±1.0%
  • LINE REGULATION±0.5%
  • LOAD REGULATION±1%
  • SETUP, RISE TIME Note.61500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
  • HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load
  • RATEDCURRENT 10A
  • INPUT
  • VOLTAGE RANGE Note.590 ~ 264VAC 127 ~ 370VDC
  • FREQUENCY RANGE47 ~ 63Hz
  • EFFICIENCY (Typ.)92.5%
  • AC CURRENT4.8A/115VAC 2.4A/230VAC
  • INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC
  • LEAKAGE CURRENT<2mA / 240VAC
  • PROTECTION
  • OVER VOLTAGE56 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
  • OVER TEMPERATUREProtection type : Shut down o/p voltage, re-power on to recover
  • ENVIRONMENT
  • WORKING TEMP.-20 ~ +70℃ (Refer to "Derating Curve")
  • WORKING HUMIDITY20 ~ 95% RH non-condensing
  • STORAGE TEMP., HUMIDITY-40 ~ +85℃ , 10 ~ 95% RH
  • TEMP. COEFFICIENT±0.03%/℃ (0~50℃)
  • VIBRATIONComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
  • SAFETY& EMC
  • SAFETY STANDARDSUL508, TUV BS EN/EN62368-1, approved;(meet BS EN/EN60204-1)
  • WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
  • ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
  • EMC EMISSIONCompliance to BS EN/EN550 2 (CISPR 2),BS EN/EN61204-3 Class B,BS EN/ 3 3 EN61000-3-2,-3,EAC TP TC 020,CNS13438 Class B
  • EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55035, EN61000-6-2 ( EN50082-2), EN61204-3, BS EN/ BS EN/ BS EN/ BS EN/ BS EN/ heavy industry level, EAC TP TC 020
  • OTHERS
  • MTBF1041.6K hrs min. Telcordia SR-332 (Bellcore) ; 146.8K hrs min. MIL-HDBK-217F (25 )
  • PACKING 1.5Kg; 8pcs/13Kg/0.9CUFT
  • Physical appearance/structure
  • Abmessungen85.5*125.2*128.5mm (W*H*D)

Spezifikation

Spezifikation
OUTPUT
  • DC VOLTAGE48V
  • RATED CURRENT(forBETypeonly) 10A
  • RATED POWER480W
  • RIPPLE & NOISE (max.) Note.3150mVp-p
  • VOLTAGE ADJ. RANGE48 ~ 55V
  • VOLTAGE TOLERANCE Note.4 ±1.0%
  • LINE REGULATION±0.5%
  • LOAD REGULATION±1%
  • SETUP, RISE TIME Note.61500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
  • HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load
  • RATEDCURRENT 10A
INPUT
  • VOLTAGE RANGE Note.590 ~ 264VAC 127 ~ 370VDC
  • FREQUENCY RANGE47 ~ 63Hz
  • EFFICIENCY (Typ.)92.5%
  • AC CURRENT4.8A/115VAC 2.4A/230VAC
  • INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC
  • LEAKAGE CURRENT<2mA / 240VAC
PROTECTION
  • OVER VOLTAGE56 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
  • OVER TEMPERATUREProtection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
  • WORKING TEMP.-20 ~ +70℃ (Refer to "Derating Curve")
  • WORKING HUMIDITY20 ~ 95% RH non-condensing
  • STORAGE TEMP., HUMIDITY-40 ~ +85℃ , 10 ~ 95% RH
  • TEMP. COEFFICIENT±0.03%/℃ (0~50℃)
  • VIBRATIONComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY& EMC
  • SAFETY STANDARDSUL508, TUV BS EN/EN62368-1, approved;(meet BS EN/EN60204-1)
  • WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
  • ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
  • EMC EMISSIONCompliance to BS EN/EN550 2 (CISPR 2),BS EN/EN61204-3 Class B,BS EN/ 3 3 EN61000-3-2,-3,EAC TP TC 020,CNS13438 Class B
  • EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55035, EN61000-6-2 ( EN50082-2), EN61204-3, BS EN/ BS EN/ BS EN/ BS EN/ BS EN/ heavy industry level, EAC TP TC 020
OTHERS
  • MTBF1041.6K hrs min. Telcordia SR-332 (Bellcore) ; 146.8K hrs min. MIL-HDBK-217F (25 )
  • PACKING 1.5Kg; 8pcs/13Kg/0.9CUFT
Physical appearance/structure
  • Abmessungen85.5*125.2*128.5mm (W*H*D)

Ressourcen

Technische Dokumente

Language: English

Diese Website verwendet essentielle Cookies und verwandte Technologien, um Ihre Cookie-Präferenzen zu speichern und Login-Funktionen zu gewährleisten. Mit Ihrem Einverständnis möchten Hikvision und zwei Partner auch optionale Cookies verwenden, um Informationen auf Ihrem Gerät zu speichern und darauf zuzugreifen, einschließlich persönlicher Informationen (z. B. IP-Adressen, Browserinformationen), um das Verkehrsaufkommen und andere Metriken zu beobachten und zu analysieren und um die Inhalte unserer Website anzupassen.

Sie können Ihre Einstellungen jederzeit ändern, indem Sie auf "Cookies verwalten" klicken. Weitere Informationen zu unseren Cookie-Praktiken finden Sie in unserer Cookie-Richtlinie und unserer Datenschutzrichtlinie.

Kontakt
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Hik-Partner Pro
Hik-Partner Pro

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.