4 Port Gigabit Unmanaged Industrial POE Switch

  • Full gigabit port
  • The backplane bandwidth is 20 Gbps
  • Supports PoE power supply and IEEE 802.3AF/AT standards.
  • The maximum output power of each PoE port is 30 W.
  • PoE management: PoE device detection and PoE power management
  • Adopt redundant dual power input design
  • Die cast aluminum alloy housing.
  • No fan, -40 °C to 75 °C operating ambient temperature.
  • MTBF ≥ 400,000 hours.
View Less
View more

Available models:

DS-3T0506P

Specification

  • General
  • ShellMetal material, fan-free design
  • Net Weight0.7 kg (1.54lb)
  • Gross Weight1.2 kg (2.65lb)
  • Dimensions (W × H × D)52.0 mm × 140.0 mm × 110.0 mm (2.05'' ×5.51'' ×4.33'')
  • Operating Temperature-40 °C to 75 °C (-40 °F to 167 °F)
  • Storage Temperature-40 °C to 85 °C (-40 °F to 185 °F)
  • Operating Humidity5% to 95% (no condensation)
  • Relative Humidity5% to 95% (no condensation)
  • Max. Power Consumption120 W
  • Power Consumption in Idle10 W
  • Surge Protection6 KV
  • Network Parameters
  • Portos4 × Gigabit RJ45 port,2 × Gigabit fiber optical port
  • MAC Address Table4 K
  • Switching Capacity20 Gbps
  • PoE Power Supply
  • PoE StandardIEEE 802.3af,IEEE 802.3at
  • PoE Power PinMid-span: 1/2(+), 3/6(-)
  • Max. Port Power30 W
  • PoE PortPoE: Ports 3 to 6
  • PoE Power Budget120 W
  • Approval
  • EMCFCC (47 CFR Part 15, Subpart B),CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020),IC (ICES-003: Issue 7:2020),RCM (AS/NZS CISPR 32: 2015)
  • SafetyUL (UL 60950-1),CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition), CE-LVD (EN 62368-1: 2014+A11: 2017)
  • ChemistryCE-RoHS (2011/65/EU)

Specification

Specification
General
  • ShellMetal material, fan-free design
  • Net Weight0.7 kg (1.54lb)
  • Gross Weight1.2 kg (2.65lb)
  • Dimensions (W × H × D)52.0 mm × 140.0 mm × 110.0 mm (2.05'' ×5.51'' ×4.33'')
  • Operating Temperature-40 °C to 75 °C (-40 °F to 167 °F)
  • Storage Temperature-40 °C to 85 °C (-40 °F to 185 °F)
  • Operating Humidity5% to 95% (no condensation)
  • Relative Humidity5% to 95% (no condensation)
  • Max. Power Consumption120 W
  • Power Consumption in Idle10 W
  • Surge Protection6 KV
Network Parameters
  • Portos4 × Gigabit RJ45 port,2 × Gigabit fiber optical port
  • MAC Address Table4 K
  • Switching Capacity20 Gbps
PoE Power Supply
  • PoE StandardIEEE 802.3af,IEEE 802.3at
  • PoE Power PinMid-span: 1/2(+), 3/6(-)
  • Max. Port Power30 W
  • PoE PortPoE: Ports 3 to 6
  • PoE Power Budget120 W
Approval
  • EMCFCC (47 CFR Part 15, Subpart B),CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020),IC (ICES-003: Issue 7:2020),RCM (AS/NZS CISPR 32: 2015)
  • SafetyUL (UL 60950-1),CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition), CE-LVD (EN 62368-1: 2014+A11: 2017)
  • ChemistryCE-RoHS (2011/65/EU)

Resources

Technical documents

Este site usa cookies para armazenar informações em seu dispositivo. Os cookies ajudam nosso site a funcionar normalmente e nos mostram como podemos melhorar sua experiência de usuário.

Ao continuar a navegar na página, concorda com a nossa política de cookies e política de privacidad.

 

Contact Us
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Hik-Partner Pro
Hik-Partner Pro

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.