Specification

  • Digital Input
  • Number of channels6 single-ended digital inputs (dry contact or common-cathode wet contact)
  • Digital input voltageDry contact Logic level 0: grounding Logic level 1: open circuit Wet contact Logic level 0: 0 to +3 V (maximum) Logic level 1: +10 V to +30 V
  • Working modeDigital input, low-to-high latch, high-to-low latch, counter, and frequency measurement
  • Counter32-bit
  • Counter/frequency input range0 to 3 kHz
  • OtherSupports inverted DI function
  • Digital Output
  • Number of channels6 form-A power relay outputs
  • Contact capacity (resistive)AC: 250 V @ 5 A DC: 30 V @ 3 A
  • Working modeDigital output, low-to-high delay output, high-to-low delay output, and frequency output
  • Breakdown voltage500 VAC (50/60 Hz)
  • Relay switching-on time7 ms
  • Relay switching-off time3 ms
  • Total operating tim10 ms
  • Insulation resistance> 1 GΩ @ 500 VDC
  • Maximum operating frequency20 cycles/min (at rated load)
  • Electrical endurance valueTypical value @30 VDC/3 A: 1 × 105 times (operating frequency: 20 cycles/min) Typical value @250 VAC/3 A: 1 × 105 times (operating frequency: 20 cycles/min)
  • Mechanical endurance valueTypical value: 2 × 107 times (no load, operating frequency: 180 cycles/min)
  • Pulse output frequency≤ 3 Hz
  • Other
  • Isolation voltage2000 V
  • Communication interface10/100 Mbps Ethernet
  • Watchdog timerDouble watchdog timers
  • Power supply voltage+10 V to 30 VDC
  • Power protectionPower reversal protection
  • Power consumption2.5 W @ 24 VDC
  • Operating temperature-10°C to +70°C
  • Storage temperature-20°C to +80°C

Specification

Specification
Digital Input
  • Number of channels6 single-ended digital inputs (dry contact or common-cathode wet contact)
  • Digital input voltageDry contact Logic level 0: grounding Logic level 1: open circuit Wet contact Logic level 0: 0 to +3 V (maximum) Logic level 1: +10 V to +30 V
  • Working modeDigital input, low-to-high latch, high-to-low latch, counter, and frequency measurement
  • Counter32-bit
  • Counter/frequency input range0 to 3 kHz
  • OtherSupports inverted DI function
Digital Output
  • Number of channels6 form-A power relay outputs
  • Contact capacity (resistive)AC: 250 V @ 5 A DC: 30 V @ 3 A
  • Working modeDigital output, low-to-high delay output, high-to-low delay output, and frequency output
  • Breakdown voltage500 VAC (50/60 Hz)
  • Relay switching-on time7 ms
  • Relay switching-off time3 ms
  • Total operating tim10 ms
  • Insulation resistance> 1 GΩ @ 500 VDC
  • Maximum operating frequency20 cycles/min (at rated load)
  • Electrical endurance valueTypical value @30 VDC/3 A: 1 × 105 times (operating frequency: 20 cycles/min) Typical value @250 VAC/3 A: 1 × 105 times (operating frequency: 20 cycles/min)
  • Mechanical endurance valueTypical value: 2 × 107 times (no load, operating frequency: 180 cycles/min)
  • Pulse output frequency≤ 3 Hz
Other
  • Isolation voltage2000 V
  • Communication interface10/100 Mbps Ethernet
  • Watchdog timerDouble watchdog timers
  • Power supply voltage+10 V to 30 VDC
  • Power protectionPower reversal protection
  • Power consumption2.5 W @ 24 VDC
  • Operating temperature-10°C to +70°C
  • Storage temperature-20°C to +80°C

Resources

Technical documents

Download Center

Hikvision.com은 웹사이트가 작동할 수 있도록 엄격히 필요한 쿠키 및 관련 기술을 사용합니다. 귀하의 동의 하에 당사는 쿠키를 사용하여 트래픽 수준 및 기타 지표를 관찰 및 분석/ 타깃 광고 표시/귀하의 위치에 따라 광고 표시/웹 사이트 콘텐츠 맞춤화를 수행하고자 합니다. 자세한 내용은 쿠키 정책을 참조하십시오.

문의하기
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Hik-Partner Pro
Hik-Partner Pro

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.