SN No. HSRC-202404-01
Modifica: Security Response Center Hikvision (HSRC)
Data di rilascio iniziale: 2024-04-02
Summary:
1. There is a NULL pointer dereference vulnerability in some Hikvision NVRs. Due to an insufficient validation of a parameter in a message, an attacker may send specially crafted messages to an affected product, causing a process abnormality.
2. There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality.
3. There is a command injection vulnerability in some Hikvision NVRs. This could allow an authenticated user with administrative rights to execute arbitrary commands.
Hikvision recommends users set up complex device passwords to mitigate the possibility of the above vulnerabilities being exploited.
CVE ID:
CVE-2024-29947
CVE-2024-29948
CVE-2024-29949
Scoring:
CVSS v3.1 is adopted in scoring these vulnerabilities
(http://www.first.org/cvss/specification-document)
CVE-2024-29947
Valore base: 2.7 (CVSS:3.1/ AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L)
CVE-2024-29948
Valore base: 3.8 (CVSS:3.1/ AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:L)
CVE-2024-29949
Valore base: 7.2 (CVSS:3.1/ AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H)
Affected Versions and Fixes:
Nome del prodotto
|
Affected by
|
Versioni interessate
|
DS-7604NI-K1 / 4P(B)
|
CVE-2024-29947 &
CVE-2024-29949
|
V4.30.096 build221220 and the versions prior to it
|
DS-7604NXI-K1/4P
|
CVE-2024-29948
|
V4.76.005 build231012 and the versions prior to it
|
DS-76xxNI-Mx
DS-77xxNI-Mx
DS-96xxxNI-Mxx
DS-76xxNXI-Ix
DS-77xxNXI-Ix
DS-86xxNXI-Ix
DS-96xxNXI-Ix
iDS-76xxNXI-Mx
iDS-77xxNXI-Mx
iDS-96xxxMXI-Mxx
|
CVE-2024-29949
|
Versions after V5.00.000 (including V5.00.000) and before V5.02.006(not including V5.02.006) |
DS-7604NI-M1/4P
|
Versions after V5.00.000 (including V5.00.000) and before V5.01.070(not including V5.01.070) |
Obtaining Fixed Versions
Users can download patches/updates on the Hikvision official website.
Source of vulnerability information
These vulnerabilities were reported to HSRC by Team.ENVY (KITRI BoB 12th).