NEW

Traffic Signal Controller

  • Modular design method,easy to install and maintain
  • Using controllable silicon to control the signal light,keeping the device stable
  • Using open, standard communication protocol, easy to extend
  • Equipped with display and control panel, which can real-time monitor and manually adjust the signal status
  • Auto-monitoring system for the communication modules and lights. It will automatically alert and react to any problems that arise
  • Equipped with independent yellow flash controller,enhancing the security;
  • Manually control the on and off of a channel/a light separately, which is convenient for wiring inspection during debugging and lamp status inspection during maintenance
  • Support online upgrades without interrupting the running of the scheme
  • Log level: debug, info, warning, error, fault
View Less
View more

Available models:

DS-TSC300-44H/HK3
DS-TSC300-44H/HK3 NEW

Specification

  • Function
  • Signal Control Board and Channel4 output board(s), supporting 44 channel(s)
  • Timing StrategySupporting 64 phases, 255 patterns, 64 plans, 255 Schemes(Adjustable on demand)
  • Signal Control Mode•Fixed Cycle: A preset time is given to each movement every cycle, Multiple phase/cycle parameters can be set in different time periods. •Full-Actuated: Real-time optimization of green light timing based on traffic data, such as lane flow, in all lanes at the intersection. •Semi-Actuated: Based on traffic data in certain lanes, such as flow, it provides real-time optimization of the green light duration for the main lanes and reduces the unnecessary green light duration for the secondary lanes. •Self-Adaptive: For congested intersection scenarios, calculate and optimize the cycle and phase durations based on historical traffic data of the all lanes to Improve the traffic efficiency. •Single-Point Optimization: According to historical and real-time traffic data, timing parameters are calculated in advance and adjusted in real time during running. •Coordinates Green wave: Consider the linkage of multiple intersections, set parameters such as phase difference, and ensure that vehicles in the main direction encounter green lights all the way. •Pedestrian Crossing: Adjust signal timing based on pedestrian in demand. •Special control: Light Disable, Yellow Flash and All red.
  • Control TypeLocal mode,web control,HCM control,manual key control,third-party platform control
  • Manual ControlAuto, Manual, Step-to-Step, Yellow Flash, All Red and Special Directional control
  • Web ConfigurationSupports web browser configuration, 3D interface display of the real-time status of the intersection
  • Time SynchronizationSupports NTP time synchronization, satellite time synchronization (GPS antenna installation required), manual time configuration, and third-party platform time synchronization
  • Countdown Timer AccessSelf-learning mode,Pulse countdown,National standard 2004/2014 mode
  • Network
  • Network ProtocolTCP/IP,HTTP,NTP, IPv4,802.1X,UDP
  • ClientHikCentral Master Lite,Hik-Central Master
  • Web BrowserChrome V61+,IE9 to IE11,Firefox V41+,Edge
  • APIconnect to the HCM through the OpenAPI,or connect the device throught NTCIP
  • SecurityPassword protection,Complicated password,802.1X authentication (EAP-PEAP, EAP-LEAP, EAP-MD5),IP address filter,Host authentication (MAC address),Security audit log,Basic and digest authentication for HTTP/HTTPS
  • Interface
  • Ethernet Interface 1 RJ45 10M/100M self-adaptive Ethernet interface
  • RS-4852 × RS-485 interface(s)
  • RS-2321 × RS-232 interface(s)
  • USB1 × USB 2.0
  • Alarm Supports 8-ch pedestrian button input(s)
  • Control Panel13 buttons: auto, manual, step-to-step, yellow flash, all red and special directional control buttons
  • Wireless Controller (Optional)5 buttons: Auto, manual, all red, yellow flash, and step-by-step control, or button customization
  • GPS (Optional)( Optional ) Support GPS Satellite Signal Real-time Timing
  • General
  • Power OutputAC 100 V to 240 V,50/60 Hz
  • Power InputAC 100 V to 240 V,50/60 Hz
  • Overall Power Consumption≤ 35 W (no load)
  • Signal Channel Consumption≤400W@AC220V;≤200W@AC110V
  • Insulation Resistance≥ 100 MΩ
  • Backup Power SupplySupports manual switching of main and backup power supply
  • Operating Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Storage Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Installation ModeFloor-standing
  • Net WeightApprox. 86.1 kg (189.82 lb.)
  • Gross WeightApprox. 93 kg (205.03 lb.)
  • Dimensions (Without Package)680 mm × 500 mm × 1081.8 mm (26.77" × 19.69" × 42.59") (L × W × H)
  • Dimensions (with Package)870 mm × 670 mm × 1270 mm (34.25" × 26.38" × 50.00") (L × W × H)
  • Cabinet MaterialSECC
  • Approval
  • EMCEN 50293:2012
  • SafetyEN IEC:62311-1:2021,EN IEC:62311-2:2021
  • EnvironmentCE-RoHS: 2011/65/EU
  • ProtectionIK10: IEC 62262:2002,IP54: IEC 60529-2013

Specification

Specification
Function
  • Signal Control Board and Channel4 output board(s), supporting 44 channel(s)
  • Timing StrategySupporting 64 phases, 255 patterns, 64 plans, 255 Schemes(Adjustable on demand)
  • Signal Control Mode•Fixed Cycle: A preset time is given to each movement every cycle, Multiple phase/cycle parameters can be set in different time periods. •Full-Actuated: Real-time optimization of green light timing based on traffic data, such as lane flow, in all lanes at the intersection. •Semi-Actuated: Based on traffic data in certain lanes, such as flow, it provides real-time optimization of the green light duration for the main lanes and reduces the unnecessary green light duration for the secondary lanes. •Self-Adaptive: For congested intersection scenarios, calculate and optimize the cycle and phase durations based on historical traffic data of the all lanes to Improve the traffic efficiency. •Single-Point Optimization: According to historical and real-time traffic data, timing parameters are calculated in advance and adjusted in real time during running. •Coordinates Green wave: Consider the linkage of multiple intersections, set parameters such as phase difference, and ensure that vehicles in the main direction encounter green lights all the way. •Pedestrian Crossing: Adjust signal timing based on pedestrian in demand. •Special control: Light Disable, Yellow Flash and All red.
  • Control TypeLocal mode,web control,HCM control,manual key control,third-party platform control
  • Manual ControlAuto, Manual, Step-to-Step, Yellow Flash, All Red and Special Directional control
  • Web ConfigurationSupports web browser configuration, 3D interface display of the real-time status of the intersection
  • Time SynchronizationSupports NTP time synchronization, satellite time synchronization (GPS antenna installation required), manual time configuration, and third-party platform time synchronization
  • Countdown Timer AccessSelf-learning mode,Pulse countdown,National standard 2004/2014 mode
Network
  • Network ProtocolTCP/IP,HTTP,NTP, IPv4,802.1X,UDP
  • ClientHikCentral Master Lite,Hik-Central Master
  • Web BrowserChrome V61+,IE9 to IE11,Firefox V41+,Edge
  • APIconnect to the HCM through the OpenAPI,or connect the device throught NTCIP
  • SecurityPassword protection,Complicated password,802.1X authentication (EAP-PEAP, EAP-LEAP, EAP-MD5),IP address filter,Host authentication (MAC address),Security audit log,Basic and digest authentication for HTTP/HTTPS
Interface
  • Ethernet Interface 1 RJ45 10M/100M self-adaptive Ethernet interface
  • RS-4852 × RS-485 interface(s)
  • RS-2321 × RS-232 interface(s)
  • USB1 × USB 2.0
  • Alarm Supports 8-ch pedestrian button input(s)
  • Control Panel13 buttons: auto, manual, step-to-step, yellow flash, all red and special directional control buttons
  • Wireless Controller (Optional)5 buttons: Auto, manual, all red, yellow flash, and step-by-step control, or button customization
  • GPS (Optional)( Optional ) Support GPS Satellite Signal Real-time Timing
General
  • Power OutputAC 100 V to 240 V,50/60 Hz
  • Power InputAC 100 V to 240 V,50/60 Hz
  • Overall Power Consumption≤ 35 W (no load)
  • Signal Channel Consumption≤400W@AC220V;≤200W@AC110V
  • Insulation Resistance≥ 100 MΩ
  • Backup Power SupplySupports manual switching of main and backup power supply
  • Operating Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Storage Condition-40 °C to 70 °C (-40 °F to 158 °F). Humidity: 95% or less (non-condensing)
  • Installation ModeFloor-standing
  • Net WeightApprox. 86.1 kg (189.82 lb.)
  • Gross WeightApprox. 93 kg (205.03 lb.)
  • Dimensions (Without Package)680 mm × 500 mm × 1081.8 mm (26.77" × 19.69" × 42.59") (L × W × H)
  • Dimensions (with Package)870 mm × 670 mm × 1270 mm (34.25" × 26.38" × 50.00") (L × W × H)
  • Cabinet MaterialSECC
Approval
  • EMCEN 50293:2012
  • SafetyEN IEC:62311-1:2021,EN IEC:62311-2:2021
  • EnvironmentCE-RoHS: 2011/65/EU
  • ProtectionIK10: IEC 62262:2002,IP54: IEC 60529-2013

Resources

Firmware

For better user experience, we highly recommend you to update your device to the latest firmware asap.

Firmware

For better user experience, we highly recommend you to update your device to the latest firmware asap.
Applied to:
DS-TSC300-44H/HK3

Hikvision.com uses strictly necessary cookies and related technologies to enable the website to function. With your consent, we would also like to use cookies to observe and analyse traffic levels and other metrics / show you targeted advertising / show you advertising on the basis of your location / tailor our website's content. For more information on cookie practices please refer to our cookie policy.

 

Contact Us
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Hik-Partner Pro
Hik-Partner Pro

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.