Specification

  • Basic Parameter
  • Fiber TypeMulti-mode
  • Channel4
  • Single-Channel Detection Range10km
  • Positioning Accuracy10km:±0.5m
  • Temperature Range-200℃~800℃(actual temperature monitoring capability depends on the selected fiber optic).
  • Temperature Accuracy±1℃
  • Temperature Resolution0.1℃
  • Spatial Resolution1m
  • Sampling Interval0.4m
  • Partition Quantity≤1000 per channel,it is configurable
  • Alarm Response Time≤5s per channel
  • Function
  • Alarm TriggerConstant Temperature Alarm, Temperature Rise Alarm, Temperature Drop Alarm, Temperature Difference Alarm
  • LED IndicatorPower indicator: Solid blue: power on Light off: power off Running indicator: Solid blue: program running normally Flashing blue: program running abnormally Fault indicator: Light off: all-in-one module running normally Solid yellow: all-in-one module error Tamper indicator: Solid red: tamper alarm triggered Light off: tamper alarm not triggered
  • BuzzerStay buzzing for tampering alarm. When the alarm information is processed or the clear alarm/mute button is pressed, the buzzer can be muted.
  • Switch1 rocker switch for power, 1 mute button, 1 clear alarm button
  • Communication
  • Communication MethodWired communication
  • Interface
  • Fiber Interface4 FC/APC fiber interfaces
  • Power Interface1 power input interface with 100~240V AC power input
  • Function Interface1 RJ45 1000 M network interface, 1 RS-232 interface, 2 RS-485 interfaces, 2 USB 3.0 interfaces
  • Alarm Out32 relay outputs
  • General
  • MaterialMetal
  • Power100-240V~50/60Hz 0.5A
  • ColorBlack
  • Power Consumption<20 W
  • Operating Temperature-15 °C to 55 °C (5 °F to 131 °F)
  • Operating Humidity0% to 95% (± 2%)
  • Laser Classification Class 1
  • Dimension133.51 mm × 483 mm × 449.21 mm (5.26" × 19.02" × 17.69")
  • Approx. 10.1 kg (22.27 lb.)

Specification

Specification
Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
  • Basic Parameter
Function
  • Function
  • Function
  • Function
  • Function
Communication
  • Communication
Interface
  • Interface
  • Interface
  • Interface
  • Interface
General
  • General
  • General
  • General
  • General
  • General
  • General
  • General
  • General
  • General

Resources

Firmware

For better user experience, we highly recommend you to update your device to the latest firmware asap.

Firmware

For better user experience, we highly recommend you to update your device to the latest firmware asap.
Applied to:
DS-QFT1004