Alarm IO Hub

  • Alarm IO Hub
  • Network
  • POE
View Less
View more

Available models:

DS-2FM2466

Specification

  • Digital Input
  • Number of channels6 single-ended digital inputs (dry contact or common-cathode wet contact)
  • Digital input voltageDry contact Logic level 0: grounding Logic level 1: open circuit Wet contact Logic level 0: 0 to +3 V (maximum) Logic level 1: +10 V to +30 V
  • Working modeDigital input, low-to-high latch, high-to-low latch, counter, and frequency measurement
  • Counter32-bit
  • Counter/frequency input range0 to 3 kHz
  • OtherSupports inverted DI function
  • Digital Output
  • Number of channels6 form-A power relay outputs
  • Contact capacity (resistive)AC: 250 V @ 5 A DC: 30 V @ 3 A
  • Working modeDigital output, low-to-high delay output, high-to-low delay output, and frequency output
  • Breakdown voltage500 VAC (50/60 Hz)
  • Relay switching-on time7 ms
  • Relay switching-off time3 ms
  • Total operating tim10 ms
  • Insulation resistance> 1 GΩ @ 500 VDC
  • Maximum operating frequency20 cycles/min (at rated load)
  • Electrical endurance valueTypical value @30 VDC/3 A: 1 × 105 times (operating frequency: 20 cycles/min) Typical value @250 VAC/3 A: 1 × 105 times (operating frequency: 20 cycles/min)
  • Mechanical endurance valueTypical value: 2 × 107 times (no load, operating frequency: 180 cycles/min)
  • Pulse output frequency≤ 3 Hz
  • Other
  • Isolation voltage2000 V
  • Communication interface10/100 Mbps Ethernet
  • Watchdog timerDouble watchdog timers
  • Power supply voltage+10 V to 30 VDC
  • Power protectionPower reversal protection
  • Power consumption2.5 W @ 24 VDC
  • Operating temperature-10°C to +70°C
  • Storage temperature-20°C to +80°C

Specification

Specification
Digital Input
  • Number of channels6 single-ended digital inputs (dry contact or common-cathode wet contact)
  • Digital input voltageDry contact Logic level 0: grounding Logic level 1: open circuit Wet contact Logic level 0: 0 to +3 V (maximum) Logic level 1: +10 V to +30 V
  • Working modeDigital input, low-to-high latch, high-to-low latch, counter, and frequency measurement
  • Counter32-bit
  • Counter/frequency input range0 to 3 kHz
  • OtherSupports inverted DI function
Digital Output
  • Number of channels6 form-A power relay outputs
  • Contact capacity (resistive)AC: 250 V @ 5 A DC: 30 V @ 3 A
  • Working modeDigital output, low-to-high delay output, high-to-low delay output, and frequency output
  • Breakdown voltage500 VAC (50/60 Hz)
  • Relay switching-on time7 ms
  • Relay switching-off time3 ms
  • Total operating tim10 ms
  • Insulation resistance> 1 GΩ @ 500 VDC
  • Maximum operating frequency20 cycles/min (at rated load)
  • Electrical endurance valueTypical value @30 VDC/3 A: 1 × 105 times (operating frequency: 20 cycles/min) Typical value @250 VAC/3 A: 1 × 105 times (operating frequency: 20 cycles/min)
  • Mechanical endurance valueTypical value: 2 × 107 times (no load, operating frequency: 180 cycles/min)
  • Pulse output frequency≤ 3 Hz
Other
  • Isolation voltage2000 V
  • Communication interface10/100 Mbps Ethernet
  • Watchdog timerDouble watchdog timers
  • Power supply voltage+10 V to 30 VDC
  • Power protectionPower reversal protection
  • Power consumption2.5 W @ 24 VDC
  • Operating temperature-10°C to +70°C
  • Storage temperature-20°C to +80°C

Download Center

Hikvision.com uses strictly necessary cookies and related technologies to enable the website to function. With your consent, we would also like to use cookies to observe and analyse traffic levels and other metrics and tailor our website’s content. For more information on cookie practices please refer to our cookie policy.

Kapcsolat
Hik-Partner Pro close
Hik-Partner Pro
Security Business Assistant. At Your Fingertips. Learn more
Hik-Partner Pro
Scan and download the app
Hik-Partner Pro
Hik-Partner Pro
back to top

Get a better browsing experience

You are using a web browser we don’t support. Please try one of the following options to have a better experience of our web content.