DS-UPS02K48-R/TS
Specifikace
Resources
Příslušenství
Data Sheet
Specifikace
Napájení
Vstup
Výstup
Baterie
Indikátor
Efficiency
životní prostředí
Physical
Standards
Napájení
UPS Capacity
2000 VA / 1800 W
Vstup
Input Voltage Range
110~300Vac (176~264Vac @ 100% load)
Input Frequency
40~70Hz (50/60Hz Auto-Sensing)
Nominal Voltage
208/220/230/240Vac
Phase
Single Phase
Power factor
≥0.99
Výstup
Output Frequency
Online mode: 46~54Hz or 56~64Hz Bat. Mode: (50/60±0.1%)Hz
Transfer Time
AC mode to Bat.mode: 0ms Inverter to Bypass: 4ms (Typical)
Output Voltage
208/220/230/240Vac
Power factor
0.9
Output Sockets
IEC panel/EU panel/UK panel/US panel Optional
Crest factor
3:1
Harmonic distortion (THDv)
≤3% Linear load ≤5% Non linear load
Output Waveform
Pure Sinewave
Baterie
Typ baterie
Valve Regulated Lead Acid (VRLA)
Typical Recharging Time
4 hours (To 90% of full capacity)
Capacity (Standard Unit)
12V/9Ah
Battery Number
4
DC System Voltage (VDC)
48V
Charging Current (Max.)
1A
Expandable Runtime
Yes, External battery pack: DS-UPSB0948B-R/TC
Typical Backup Time
View Runtime Graph
Indikátor
Alarm
Battery mode/Battery low voltage /Overload/Fault
LCD displej
Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Efficiency
AC Mode
91%
Battery Mode
87%
životní prostředí
Provozní teplota
0°C~40°C
Skladovací teplota
-25°C~55°C
Humidity Range
20~95%RH @ 0~40°C (Non condensing)
Altitude
<1500m, derating required when>1500m
Noise Level
<55dB at 1 Meter
Physical
Dimension W x D x H (mm)
191 x 460 x 337
Net weight (kg)
19.5
Standards
Bezpečnost
CE-LVD, IEC/EN 62040-1, IEC/EN 62477-1
EMC
CE-EMC, IEC/EN 62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Specifikace
Napájení
UPS Capacity
2000 VA / 1800 W
Vstup
Input Voltage Range
110~300Vac (176~264Vac @ 100% load)
Input Frequency
40~70Hz (50/60Hz Auto-Sensing)
Nominal Voltage
208/220/230/240Vac
Phase
Single Phase
Power factor
≥0.99
Výstup
Output Frequency
Online mode: 46~54Hz or 56~64Hz Bat. Mode: (50/60±0.1%)Hz
Transfer Time
AC mode to Bat.mode: 0ms Inverter to Bypass: 4ms (Typical)
Output Voltage
208/220/230/240Vac
Power factor
0.9
Output Sockets
IEC panel/EU panel/UK panel/US panel Optional
Crest factor
3:1
Harmonic distortion (THDv)
≤3% Linear load ≤5% Non linear load
Output Waveform
Pure Sinewave
Baterie
Typ baterie
Valve Regulated Lead Acid (VRLA)
Typical Recharging Time
4 hours (To 90% of full capacity)
Capacity (Standard Unit)
12V/9Ah
Battery Number
4
DC System Voltage (VDC)
48V
Charging Current (Max.)
1A
Expandable Runtime
Yes, External battery pack: DS-UPSB0948B-R/TC
Typical Backup Time
View Runtime Graph
Indikátor
Alarm
Battery mode/Battery low voltage /Overload/Fault
LCD displej
Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time
Efficiency
AC Mode
91%
Battery Mode
87%
životní prostředí
Provozní teplota
0°C~40°C
Skladovací teplota
-25°C~55°C
Humidity Range
20~95%RH @ 0~40°C (Non condensing)
Altitude
<1500m, derating required when>1500m
Noise Level
<55dB at 1 Meter
Physical
Dimension W x D x H (mm)
191 x 460 x 337
Net weight (kg)
19.5
Standards
Bezpečnost
CE-LVD, IEC/EN 62040-1, IEC/EN 62477-1
EMC
CE-EMC, IEC/EN 62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
Specifikace
Napájení
Napájení
Vstup
Vstup
Vstup
Vstup
Vstup
Vstup
Výstup
Výstup
Výstup
Výstup
Výstup
Výstup
Výstup
Výstup
Výstup
Baterie
Baterie
Baterie
Baterie
Baterie
Baterie
Baterie
Baterie
Baterie
Indikátor
Indikátor
Indikátor
Efficiency
Efficiency
Efficiency
životní prostředí
životní prostředí
životní prostředí
životní prostředí
životní prostředí
životní prostředí
Physical
Physical
Physical
Standards
Standards
Standards
Resources
Technical documents
Data Sheet
User Manual
Příslušenství
NEW
DS-UPSB0948B-R/TC
48Vdc, External battery pack for use with 2KVA UPS,with 8 PCS of 9Ah built-in battery;
Porovnání