EOL

Thermal & Optical Bi-spectrum Network Bullet Camera

  • 384 × 288 resolution, 17 μm, VOx UFPA, NETD < 35 mK (25 °C, F# = 1.0)
  • Temperature exception alarm for fire prevention, -20°C to 150°C (-4°F to 302°F), ± 8°C (± 14.4°F)
  • Image processing technology: linear, histogram, self-adaptive thermal AGC mode, DDE, 3D DNR
  • Fire detection algorithm
  • High quality detector with 10 years guarantee
View Less
View more

Available models:

DS-2TD2637-10/PY

Specification

  • Thermal Module
  • Image SensorVanadium Oxide Uncooled Focal Plane Arrays
  • Resolution384 × 288
  • Pixel Interval17 μm
  • Response Waveband8 μm to 14 μm
  • NETDLess than 35 mK (@25 °C,F#=1.0)
  • Focal Length9.7 mm
  • IFOV1.75 mrad
  • Field of View37.5° × 28.5° (H × V)
  • Min. Focusing Distance1 m
  • ApertureF1.0
  • Digital Zoom×2, ×4, ×8
  • Optical Module
  • Image Sensor1/2.7" Progressive Scan CMOS
  • Resolution2688 × 1520, 4 MP
  • Min. IlluminationColor: 0.0089 Lux @(F1.6, AGC ON), B/W: 0.0018 Lux @(F1.6, AGC ON)
  • Shutter Speed1s to 1/100,000s
  • Focal Length4 mm
  • Field of View84° × 44.8° (H × V)
  • Aperture (Range)F1.6
  • WDR120 dB
  • Image Effect
  • Bi-spectrum Image FusionDisplay the details of optical channel on thermal channel
  • Picture in PictureDisplay partial image of thermal channel on the full screen of optical channel
  • Target ColorationYes. Supported in white hot and black hot mode.
  • Illuminator
  • IR DistanceUp to 40 m
  • IR Intensity and AngleAutomatically adjusted
  • Smart Function
  • VCA4 VCA rule types (line crossing, intrusion, region entrance, and region exiting), up to 8 VCA rules in total.
  • Temperature Measurement3 temperature measurement rule types, 21 rules in total (10 points, 10 areas, and 1 line).
  • Temperature Range-20 °C to 150 °C (-4 °F to 302 °F)
  • Temperature Accuracy± 8 °C (±14.4 °F)
  • Fire DetectionDynamic fire detection, up to 10 fire points detectable.
  • Video and Audio
  • Main Stream